CTC AGL PRODUCTS

AGL SECONDARY
CONNECTOR KITS

Field-attachable secondary connector kit designed to provide a watertight electrical connection between AGL isolating transformer secondary leads and airfield lighting fittings or secondary cables.

FEATURES & ENGINEERING

Engineered for reliable and secure AGL secondary-circuit connections.

01

Field-Attachable Construction

Designed for field installation and connection according to the approved assembly procedure.

02

Watertight Connection

Elastomeric molded insert provides reliable watertight protection for outdoor and underground AGL applications.

03

2-Core Secondary Cable Compatibility

Designed for 2 × 2.5/4 mm² secondary AGL cable used on the secondary side of isolating transformers.

04

Environmental Resistance

Designed to withstand demanding AGL conditions including water, soil, fuel, alkali, acid, de-icing agents, ozone and weathering.

05

Reliable Electrical Contact

Copper-alloy, tin-plated crimp contacts provide the specified electrical connection.

06

Direct Burial & Base-Can Ready

Suitable for direct burial and base-can applications as specified in the TDS.

PRODUCT RANGE & TECHNICAL SPECIFICATIONS

CTC38S

Secondary Connector Kit

2 × 2.5/4 mm² 2-core secondary AGL cable FAA AC 150/5345-26E (L-823)
KEY TECHNICAL DATA
PRIMARY VOLTAGE 600 V BETWEEN CONTACTS
NOMINAL CURRENT 20 A
FREQUENCY 50 / 60 Hz
OPERATING TEMPERATURE −55°C to +65°C
CLASSIFICATION Type II / Class B
STANDARD FAA L-823 Style 5/12

BUILT FOR AIRFIELD LIGHTING SYSTEMS

Reliable secondary-circuit connections for demanding airport ground lighting installations.

01

RUNWAY LIGHTING

Suitable for secondary connections used with runway edge lighting systems.

→
02

TAXIWAY LIGHTING

Designed for secondary-side connections in taxiway edge lighting applications.

→
03

THRESHOLD & RUNWAY-END LIGHTING

Applicable to transformer-fed threshold and runway-end light fittings.

→
04

STOP-BAR LIGHTING

Suitable for secondary connections used in stop-bar lighting systems.

→
05

GUIDANCE SIGNS

Can be used with AGL guidance signs supplied through isolating transformers.

→
06

AGL LIGHTING FIXTURES

Designed for secondary connections associated with transformer-fed AGL fixtures.

→
AGL Light Fitting → Secondary Connector → Secondary Cable → Isolating Transformer

FREQUENTLY ASKED QUESTIONS

A secondary connector kit provides the electrical connection between the secondary side of an AGL isolating transformer and the connected airfield lighting circuit or fitting.

The specified model is CTC38S.

The specified conductor configuration is 2 × 2.5/4 mm².

The CTC38S uses a twin-conductor receptacle, FAA L-823 Style 5/12.

Yes. The TDS specifies compatibility with direct burial and base-can applications and states that the connector is submersible in water and soil.

The specified voltage drop is ≤ 6.0 mV at 20 A.

Looking for the Right OCEM Airfield Lighting Solution?

Explore our range of OCEM airfield lighting products for runway and taxiway systems, PAPI, approach lighting, illuminated guidance signs, and AGL control systems.