CTC AGL PRODUCTS
AGL CABLE JOINT KIT
Cable Jointing Solutions for Airfield Ground Lighting Systems
CTC AGL Cable Joint Kits are designed for jointing and repairing underground Airfield Ground Lighting (AGL) cable systems. They support applications such as new cable installation, cable extension, damaged cable replacement, maintenance and circuit modification.
The jointing solution is designed to maintain electrical continuity, insulation integrity, environmental protection and mechanical integrity for the specified cable and installation environment.
AGL Cable Joint Kits for Critical Jointing Applications
CTC AGL Cable Joint Kits are designed for jointing and repairing underground Airfield Ground Lighting cable systems. The suitable jointing solution depends on the cable construction, cable size, voltage, jointing method and project requirements.
AGL Cable Jointing Applications
Primary AGL Cable
Applicable jointing solutions for primary underground AGL cable circuits where the specified jointing method is required.
Secondary AGL Cable
Jointing solutions for applicable secondary AGL cable connections according to the cable construction and system requirements.
Runway Circuits
Applicable cable jointing solutions for runway lighting circuits and associated underground AGL cable networks.
Taxiway Circuits
Suitable jointing applications for underground cable connections serving applicable taxiway lighting circuits.
Approach Circuits
Cable jointing solutions for applicable approach lighting circuits and underground AGL cable networks.
Cable Repair & Extension
Applicable for underground cable repairs, damaged cable replacement and extension of existing AGL cable runs.
AGL Cable Joint Kit Functions
Electrical Connection
Provides a secure electrical connection between the applicable cable conductors.
Insulation
Maintains the required insulation system around the completed cable joint.
Environmental Protection
Helps protect the completed joint against moisture and environmental exposure.
Mechanical Protection
Provides protection to the completed joint against mechanical stresses associated with installation.
The correct cable joint kit must be selected according to cable construction, cable size, voltage, jointing method and applicable project requirements.
Structured Cable Jointing for Reliable AGL Connections
An AGL cable joint combines conductor connection, insulation, sealing and mechanical protection to create a completed joint suitable for the specified cable and installation environment. The exact component arrangement should follow the applicable CTC product datasheet and approved installation procedure.
AGL Cable
Specified AGL cable prepared according to the applicable cable jointing procedure.
Cable Preparation
The cable is prepared to the required dimensions before completing the electrical joint.
Conductor Connection
Cable conductors are connected using the specified cable jointing components.
Insulation System
The completed electrical connection is insulated using the applicable insulation system.
Sealing & Protection
The joint is sealed and protected against moisture and environmental exposure.
Cable Connector
Provides the required conductor connection for the specified cable configuration.
Joint Body
Provides the main structure around the completed cable connection and joint assembly.
Sealing System
Helps protect the completed joint against moisture and environmental ingress.
Protective Outer Layer
Provides additional protection around the completed cable joint.
Mechanical Components
Support the required mechanical integrity of the completed joint assembly.
Follow the Approved Jointing Arrangement
The exact component set, dimensions, materials and jointing arrangement must be confirmed from the applicable CTC product datasheet and approved installation procedure for the specified cable and project requirements.
Select the Correct Joint Kit for the Specified AGL Cable
Correct cable joint kit selection is essential for maintaining the electrical and mechanical integrity of an AGL cable system. The joint kit should be selected after verifying the cable construction, electrical characteristics, installation environment and applicable project requirements.
Selection Parameters
Cable Voltage
Confirm the operating voltage of the AGL cable circuit.
Cable Type
Identify the exact cable type and construction before selecting the applicable joint kit.
Cable Size
Confirm the applicable cable size required for the jointing application.
Conductor Material
Verify the conductor material according to the cable construction.
Number of Conductors
Confirm the number of conductors included in the specified cable.
Insulation
Identify the cable insulation type and applicable requirements.
Installation Environment
Confirm whether the joint will be installed underground or in another specified environment.
Jointing Method
Select the joint kit according to the specified or approved jointing method.
Project Standard
Verify the applicable airport, project or technical standard.
Joint Kit Selection Verification
Identify
Identify the cable make, type, size and construction.
Confirm
Confirm voltage, conductor material, number of conductors and insulation.
Verify
Verify the installation environment, jointing method and applicable project requirements.
Match
Match the joint kit with the confirmed cable and technical requirements.
Confirm
Confirm the applicable jointing arrangement and component configuration.
Prepare
Ensure the required joint kit and installation components are available before starting the work.
Proceed
Proceed with installation only after the joint kit has been verified against the applicable cable and project requirements.
The correct AGL Cable Joint Kit must match the cable voltage, type, size, conductor configuration, insulation, installation environment, jointing method and applicable project standard.
AGL Cable Joint Installation, Testing & Quality Verification
Correct installation and verification are essential to maintain the electrical continuity, insulation integrity, sealing and mechanical protection of an AGL cable joint. Installation should follow the approved procedure and applicable project requirements.
Installation Procedure
Isolate the Circuit
De-energise and isolate the applicable circuit according to airport safety procedures.
Identify the Cable
Confirm the cable type, size, circuit and applicable joint kit before starting the work.
Prepare the Cable
Prepare the cable according to the specified dimensions and approved jointing procedure.
Complete the Electrical Joint
Make the conductor connection using the specified jointing components.
Apply Insulation
Complete the required insulation system around the electrical connection.
Seal the Joint
Apply the specified sealing and protective components to protect against environmental exposure.
Inspect
Visually inspect the completed joint for correct assembly, sealing and mechanical integrity.
Test
Carry out the required electrical tests according to the cable specification and project requirements.
Testing & Quality Verification
Verify the completed cable joint against the applicable cable, installation and project requirements.
Continuity
Verify electrical continuity through the completed cable joint.
Insulation Resistance
Check insulation resistance as required for the applicable cable and project.
High-Voltage Test
Perform high-voltage testing where required by the applicable specification.
Phase / Circuit Identification
Confirm correct phase or circuit identification where applicable.
Visual Inspection
Check the completed joint, cable preparation and component arrangement.
Joint Sealing Inspection
Verify that the joint sealing system has been correctly applied.
Verify Every AGL Cable Joint Before Energisation
Confirm correct cable identification, joint kit selection, cable preparation, conductor connection, insulation, sealing, mechanical integrity and required electrical testing before the completed joint is placed into service.
FREQUENTLY ASKED QUESTIONS
An AGL Cable Joint Kit is used for jointing and repairing underground Airfield Ground Lighting cable systems while maintaining electrical continuity, insulation integrity, environmental protection and mechanical integrity.
AGL Cable Joint Kits can be used for applicable primary and secondary AGL cables, runway circuits, taxiway circuits, approach circuits, underground cable repairs and cable extensions.
No. The correct kit depends on the cable type, size, voltage, conductor configuration, insulation, installation environment, jointing method and applicable project requirements.
Yes. Applicable cable joint kits can be used for underground cable repairs and damaged cable replacement, subject to correct kit selection and the approved installation procedure.
The cable joint should be installed by suitably qualified personnel following the applicable safety requirements, product instructions and approved installation procedure.
Please provide the cable make, cable type, cable size, voltage, number of conductors, insulation, installation environment, jointing method and applicable project specification.
Looking for the Right OCEM Airfield Lighting Solution?
Explore our range of OCEM airfield lighting products for runway and taxiway systems, PAPI, approach lighting, illuminated guidance signs, and AGL control systems.