CTC AGL PRODUCTS

AGL ISOLATING
TRANSFORMERS

CTC AGL Isolating Transformers are designed for 5 kV constant-current series circuits used in Airfield Ground Lighting systems, providing electrical isolation between the primary AGL circuit and the connected airfield lighting fixture.

ENGINEERED FOR AIRFIELD ENVIRONMENTS

Built for Demanding AGL Applications

Designed around the requirements of airport series-circuit lighting systems, with emphasis on isolation, environmental resistance and robust field installation.

CTC AGL Isolating Transformer
5 kV SERIES CIRCUIT
WATERTIGHT CONSTRUCTION
TPV RUBBER ENCAPSULATION
FIELD INSTALLATION
01

Series-to-Series Electrical Isolation

Electrical isolation between the series circuit and the connected AGL fixture.

02

5 kV AGL Series-Circuit Design

Application for 5 kV constant-current AGL series circuits.

03

TPV Rubber Encapsulation

Watertight TPE/TPV rubber compound enclosure construction.

04

Watertight Construction

Construction intended for demanding outdoor and buried installation conditions.

05

Environmental Resistance

Specified for an ambient temperature range of –55°C to +65°C.

06

Direct Burial and Base Mounting

Installation options include outdoor, buried and in-base-can applications.

07

Robust Mechanical Construction

Product construction intended for airport-ground-lighting environments.

08

Connector-Compatible Configuration

L-823 style connector configurations as specified for the product.

PRODUCT RANGE

Select the right configuration for your AGL application.

Available ratings for applicable airport series-circuit lighting requirements.

Product Range

Available transformer ratings for AGL series-circuit applications.

RATING PRIMARY CURRENT FREQUENCY
15 W 6.6 A / 20 A 50 / 60 Hz
25 W 6.6 A / 20 A 50 / 60 Hz
45 W 6.6 A / 20 A 50 / 60 Hz
65 W 6.6 A / 20 A 50 / 60 Hz
100 W 6.6 A / 20 A 50 / 60 Hz
150 W 6.6 A / 20 A 50 / 60 Hz
200 W 6.6 A / 20 A 50 / 60 Hz
300 W 6.6 A / 20 A 50 / 60 Hz

Engineering Data at a Glance

Key technical parameters for the AGL isolating transformer range.

⌘
APPLICATION

5 kV constant-current series circuit for AGL systems

≋
FREQUENCY

50 Hz / 60 Hz

⚡
CURRENT RATING

6.6 A and 20 A

°
AMBIENT TEMPERATURE

–55°C to +65°C

◆
INSTALLATION

Outdoor / Buried / In Base Can

◇
ENCLOSURE

Watertight TPE/TPV rubber compound

✣
COOLING

Natural air and soil contact

↗
MINIMUM POWER FACTOR

0.95

Technical Reference

ENGINEERING REFERENCE

Product Information Architecture

Review the available technical reference categories below without overcrowding the primary specification table.

01
Construction & Housing

Watertight TPE/TPV rubber compound housing and applicable installation arrangements.

02
Electrical Insulation & Performance

Series-to-series electrical isolation within the AGL series circuit.

03
Leads & Connectors

L-823 style connector configurations according to applicable product documentation.

04
Performance

Applicable ratings, circuit current and operating frequency information.

05
Testing & Quality Assurance

Technical testing and quality requirements associated with the applicable product documentation.

06
Environmental Performance

Environmental operating range and weather-resistant construction.

APPLICATIONS

Designed for Critical AGL Applications

CTC AGL Isolating Transformers are designed for applicable airport series-circuit lighting applications across runway, taxiway and airfield lighting infrastructure.

01

Runway Edge Lights

Supports applicable runway edge lighting configurations within AGL series circuits.

→
02

Taxiway Edge Lights

Suitable for applicable taxiway edge lighting installations and series-circuit applications.

→
03

Threshold & Runway-End Lights

Applicable to threshold and runway-end lighting configurations used within airport lighting systems.

→
04

Stop Bar Lights

Supports applicable stop bar lighting installations within AGL series circuits.

→
05

Lead-On / Lead-Off Lights

Applicable for lead-on and lead-off lighting arrangements used in airport environments.

→
06

Guidance Signs

Applicable to airport guidance signage configurations connected to AGL systems.

→
07

Elevated Light Fittings

Suitable for applicable elevated airfield lighting fixture configurations.

→
08

Inset Light Fittings

Applicable for inset airfield lighting fixture configurations within series circuits.

→
01 CCR Constant Current
Regulator
02 PRIMARY AGL
CABLE
Series Circuit
03 PRIMARY
CONNECTOR
Primary Connection
04 AGL ISOLATING
TRANSFORMER
Electrical Isolation
05 SECONDARY
CONNECTOR
Secondary Connection
06 AGL LIGHT Airfield Fixture
FREQUENTLY ASKED QUESTIONS

Frequently Asked Questions

Technical answers to common questions about CTC AGL Isolating Transformers.

An AGL isolating transformer provides electrical isolation between the airport series circuit and the connected airfield lighting fixture.

Available ratings include 15 W, 25 W, 45 W, 65 W, 100 W, 150 W, 200 W and 300 W.

The transformer range supports primary circuit current ratings of 6.6 A and 20 A.

The applicable transformer range is designed for 50 Hz and 60 Hz series-circuit applications.

Yes. Applicable installation options include outdoor, buried and in-base-can installation.

The transformer uses a watertight TPE/TPV rubber compound enclosure construction.

L-823 style connector configurations are available according to the applicable product configuration and product documentation.

Applicable product requirements and technical documentation should be reviewed for the relevant project specifications and referenced standards.

Looking for the Right OCEM Airfield Lighting Solution?

Explore our range of OCEM airfield lighting products for runway and taxiway systems, PAPI, approach lighting, illuminated guidance signs, and AGL control systems.